Odors permeate in the room during operation. What could be the problem with a system please help. You also have the option to opt-out of these cookies. Is the selected temperature too high? Check Comp wire. Diagnosis coding under this system uses 3–7 alpha and numeric digits The ICD-10 procedure coding system uses 7 alpha or numeric digits Dotted Code: E55.9: ICD-10-CM or ICD-10-PCS code value. ICD-10-CM Diagnosis Code E55.9. This website uses cookies to improve your experience while you navigate through the website. Outdoor unit EEPROM Read/Write error (Option). Error on room temperature sensor of indoor unit (Short or Open). (White), Indoor unit Eva In sensor (Open/Short) Check indoor unit pipe sensor. This may save time and unnecessary expenses. Check whether the outdoor unitservice valve is open. Der Fehlercode zeigt an, ob das Problem bei der Samsung AC-Inneneinheit oder der Samsung AC-Außeneinheit liegt. Lascia anche tu il tuo commento. Check indoor unit PCB connector CN41. I have a error code E500 contact failure on IPM of inverter PBA1 If the indicator is still blinking, contact the service center. No communication for 2 minutes between indoor and outdoor unit (communication error for more than 2minutes). Problem: The unit does not operate immediately after restarting it. Check the connection status of the motor and the outdoor unit PCB. Refill the coolant after checking the leaking part. Water is dropping from the outdoor unit piping connection. Check coolant charging Check the compressor connection status and normal operation Check the obstacles around the indoor and outdoor units Check whether the outdoor unitservice valve is open Check whether the indoor/outdoor installation pipe/ wiring are correct, Compressor V limit error. Check Outdoor Inverter PBA. What should I do? Error due to abnormal rotation of the compressor or unconnected wire of compressor. It is mandatory to procure user consent prior to running these cookies on your website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Is the detection part of the indoor unit blocked? our company provides service for products like refrigerator,AC, washing machine,microwave oven, Air conditioner. Plug in orswitch on the circuit breaker and then operate the air conditioner again. Check the normal operation of outdoor fan. E-163: Indoor unit’s remote controller option input is Incorrect or missing. Check input power. Indoor unit EVA_IN Thermistor Open/Short. You also have the option to opt-out of these cookies. I have a problem in Samsung inverter split a.c unit.indoor unit show error E109.What its means and what should I do.please help. All rights reserved. any ideas what i have to check? COND temperature sensor error. Gas leak error. Pur nella consapevolezza della natura dell'errore (sapevano benissimo che si trattava di e559 combinato con e190) il tecnico ha soltanto controllato la … to admin..i also have error code e485 input current sensor error..im a retired hvac tech but have very little exp on mini splits..from what i have read says check power i did that its ok..then said replace pcb which i have on order..could anything else cause it as i dont have tools anymore and samsung tech wont talk to me.i had to order the board through a samsung service company here..could condenser fan motor cause that error?..i found a code for bad motor online e458 but i dont get that just e485. Fehlercodeliste für Samsung Split System-Klimaanlagen. The technician check & simply changed Motor, then it working and charged my huge amount E-212: If the rotary switch (on the MCU) for address setting of the indoor unit has 3 or more of the same address, E-213: When total number of indoor units assigned to MCU is same as actual number of installed indoor units but there is indoor unit that is not installed even though it is assigned on MCU, E-214: When number of MCU is not set correctly on the outdoor unit or when two or more MCU was installed some of them have the same address, E-215: When two different MCU’s have same address value on the rotary switch. It’s a normal thing, because you deal with the technological stuff made by human. Error on outdoor temperature sensor (Short or Open). Error on DC-Link voltage sensor (Short or Open). Indoor unit communication error. Change the outdoor unit location and direction. Pressthe Power button or disconnect the power plug/switch off the auxiliary power switch. Check the normal operation of PCB. This site uses cookies to personalise your experience, analyse site traffic and keep track of items stored in your shopping basket. (We do not use smelly componentsin the air conditioner.). PFC Overload (Over current) Error. Ecco una lista di opinioni su climatizzatori samsung errore e5 59. Check AC power connection. Is the selected temperature too low? Some of error code requires activities exclusively for Authorise Service Center. Samsung AC Display Error and Check Method: If you turn off the air conditioner when the LED is flickering, the LED is also turned off. Does it interfered with the radio of neon sign? Called the person who installed it and he tells me he will come and look at . Everyone I talk to does not install this brand . Gas leak detected. System stop due to overload protection control. Depending on the status of the air conditioner usage, noise can be heard when refrigerant flow movement changes. [Inverter] Total current error/ PFC over current error. Check the option code of the indoor unit. Check the communication cable of indoor unit. Error on thermal fuse of indoor unit (Open). Check the resistance between difference phases of the compressor. Outdoor temperature sensor error. Error on EVA OUT sensor of indoor unit (Short or Open). Check the operation setting state . Outdoor unit EEPROM Read/Write error (H/W). DC LINK over/low voltage error. Wenn auf Ihrem Samsung AC Fehlercodes angezeigt werden, werden Sie auf ein Problem aufmerksam gemacht. ); Trouble: The wind comes out but the heating/cooling is not performed. Error of the outdoor temperature sensor. Check MAIN MICOM . Troubleshooting. Check that Com1, Com2 setting DIP switch isset to Com2. Buonasera, mi sono appena iscritta sperando di poter trovare una soluzione al mio problema. This website uses cookies to improve your experience while you navigate through the website. Check if you have set theOffTimer.Operate the air conditioner again by pressing the Power button. Check indoor unit floatsensor. Check for leaksfrom the connection part of the pipe and product or from the pipe joint. -Heatsink sensor error. Close the doors and windows. Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. Check sensor connection status. Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. Error on discharge temperature sensor of compressor 1 (Short or Open). (DISCHARGE temperature control). Check electrical connection and setting, Outdoor communication error between main micom and inverter micom, Outdoor communication error beween main micom and hub micom, Outside temperature sensor error(Short/Open) - Error level: over 4.9V(-50°C) under 0.4V(93°C), Condenser temperature sensor error(Short/Open) - Error level: over 4.9V(-50°C) under 0.4V(93°C), Outdoor unit sensor error - Condenser out sensor(Short/Open) - Self diagnosis, Compressor Discharge temperature sensor error, Compressor discharge sensor detached - Self diagnosis, Compressor OLP sensor error (Short/Open) - Error condition : outdoor temperature under -20°C - Error level : over 4.95V(-30°C) under 0.5V(151°C), Outdoor unit freezing(Compressor stop). Ho da poco acquistato il condizionatore modello AJ050NCJ2EG.. Dopo pochi minuti dall'installazione l'unità interna ha dato errore E559 (ho letto altre discussioni su altri modelli con lo stesso errore e mi pare di capire che si tratti di un errore dell'unità esterna). Communication error between indoor/outdoor INV-MAIN MICOM (1 min). Trouble: The remote control does not operate, Trouble: The operation lamp continues to be flickering, Trouble: The immediate operation starts without control of remote control when plugged, Cause and reason: It is the case that the auto restart function works. Check the connection of the pipes. Compressor LOCK error. Were you able to get this resolved? Indoor unit EVA_OUT Thermistor Open/Short. A Samsung representative at Best Buy can set up a personal demonstration for your next galaxy device. and the list goes on and on and on they even promised to replace it but that never eventuated…, its e203 communication error…lose or bad wire between indoor and outdoor unit. Auto restart function is the convenient function where the operation state is memorized in the Memory IC during the blackout and the operation restarts when the power comes back, Samsung Wind Free™ Air Conditioner : Fast Cooling Test, Samsung Split Type Air Conditioner Service Manual PDF, Samsung Multi Air Conditioner Service Manual PDF, DVM S Service Manuals_DVM S Outdoor Unit Service Manual PDF, Samsung official site: https://www.samsung.com/levant/air-conditioners. The temperature setting is not required since the wind volume set automatically. Galaxy E5. Is the operation selected among the Dry / Turbo / Sleeping / Fan only Mode. From a Home screen, tap Apps > Settings. A Samsung representative at Best Buy will call to schedule your Galaxy S10 try out. Since the temperature is automatically set, the temperature setting is not required. Communication error between the Master and Slave wired remote controllers. Ventilate the room or operate the air conditioner in Fan mode for 1~2 hours. Joseph, Your email address will not be published. This week, in Newark, New Jersey, consumers filed an attempted class-action claim against Samsung, claiming that the company's washing machines (specifical Check the operation of the indoor fan. IPM Overheat Error for Outdoor Unit Inverter Comp. Check again at the cooling / heating state. when it starts. SAMSUNG SPLIT-TYPE AIR CONDITIONER SERVICE TROUBLESHOOTING MANUAL IN PDF SAMSUNG SPLIT-TYPE AIR CONDITIONER SERVICE MANUAL – PDF Check Discharge sensor Open / Short. Check Outdoor Inverter PBA. Comment:*document.getElementById("comment").setAttribute( "id", "ae7537db3f51a30f0f34d9b0e6a03e6a" );document.getElementById("g2bf16c3b0").setAttribute( "id", "comment" ); Save my name, email, and website in this browser for the next time I comment. Stops). Check OLP sensor Open / Short. Check electrical connection and setting between indoor unit MAIN PBA - INVERTER PBA. Check the compressor connection status. Check sensor location. Check the normal operation of PCB. The unit will start in 3 minutes. This website uses cookies to improve your experience while you navigate through the website. Change the location of the outdoor unit if the temperature is abnormally high when the heatproof plate is checked. E-217: hen indoor unit is connected to a MCU port but indoor unit is assigned to a MCU and the switch on the port is set to Off, E-218: When there’s at least one or more actual number of indoor unit connection compared to number of indoor units assigned to MCU, E-219: Error on temperature sensor located on MCU intercooler inlet, E-220: Error on temperature sensor located on MCU intercooler outlet, E-221: Error on outdoor temperature sensor of outdoor unit, E-231: Error on COND OUT temperature sensor of main outdoor unit, E-251: Error on discharge temperature sensor of compressor 1, E-257: Error on discharge temperature sensor of compressor 2, E-262: Discharge temperature sensor of compressor 1 is detached from the sensor holder on the pipe, E-263: Discharge temperature sensor of compressor 2 is detached from the sensor holder on the pipe, E-266: Top sensor of compressor 1 is detached, E-267: Top sensor of compressor 2 is detached, E-269: Suction temperature sensor is detached from the sensor holder on the pipe, E-276: Error on top sensor of compressor 1 (Short or Open), E-277: Error on top sensor of compressor 2 (Short or Open), E-291: Refrigerant leakage or error on high pressure sensor (Short or Open), E-296: Refrigerant leakage or error on low pressure sensor (Short or Open), E-308: Error on suction temperature sensor (Short or Open), E-311: Error on temperature sensor of double layer pipe/liquid pipe(sub heat exchanger) (Short or Open), E-321: Error on EVI (ESC) IN temperature sensor (Short or Open), E-322: Error on EVI (ESC) OUT temperature sensor (Short or Open), E-323: Error on suction sensor 2 (Short or Open), E-346: Error due to operation failure of Fan2, E-347: Motor wire of Fan2 is not connected, E-348: Lock error on Fan2 of outdoor unit, E-353: Error due to overheated motor of outdoor unit’s Fan2, E-355: Error due to overheated IPM of Fan2, E-361: Error due to operation failure of inverter compressor 2, E-364: Error due to over-current of inverter compressor 2, E-365: V-limit error of inverter compressor 2, E-366: Error due to over voltage /low voltage of inverter PBA2, E-367: Error due to unconnected wire of compressor 2, E-368: Output current sensor error of inverter PBA2, E-369: DC voltage sensor error of inverter PBA2, E-374: Heat sink temperature sensor error of inverter PBA2, E-385: Error due to input current of inverter 2, E-386: Over-voltage/low-voltage error of Fan2, E-389: V-limit error on Fan2 of compressor, E-393: Output current sensor error of Fan2, E-399: Heat sink temperature sensor error of Fan2, E-400: Error due to overheat caused by contact failure on IPM of Inverter PBA2, E-407: Compressor operation stop due to high pressure protection control, E-410: Compressor operation stop due to low pressure protection control or refrigerant leakage, E-416: Compressor operation stop due to discharge temperature protection control, E-425: Phase reversal or phase failure (3Ø outdoor unit wiring, R-S-T-N ), connection error on 3 phase input, E-428: Compressor operation stop due abnormal compression ratio, E-438: EVI (ESC) EEV leakage or internal leakage of intercooler or incorrect connector insertion of EVI, E-440: Heating mode restriction due to high air temperature, E-441: Cooling mode restriction due to low air temperature, E-442: Refrigerant charing restriction in heating mode when air temperature is over 15 °C, E-443: Operation prohibited due to low pressure, E-446: Error due to operation failure of Fan1, E-447: Motor wire of Fan1 is not connected, E-452: Error due to ZPC detection circuit problem or power failure, E-453: Error due to overheated motor of outdoor unit’s Fan1, E-455: Error due to overheated IPM of Fan1, E-461: Error due to operation failure of inverter compressor 1, E-462: Compressor stop due to full current control or error due to low current on CT2, E-464: Error due to over-current of inverter compressor 1, E-465: V-limit error of inverter compressor 1, E-466: Error due to over voltage /low voltage of inveter PBA1, E-467: Error due to unconnected wire of compressor 1, E-468: Output current sensor error of inverter PBA1, E-469: DC voltage sensor error of inver PBA1, E-474: Heat sink temperature sensor error of inverter PBA1, E-485: Error due to input current of inverter 1, E-486: Error due to over voltage/low voltage of Fan, E-489: V-limit error on Fan1 of compressor, E-493: Output current sensor error of Fan1, E-499: Heat sink temperature sensor error of Fan1, E-500: Error due to overheat caused by contact failure on IPM of Inverter PBA1, E-503: Error due to alert the user to check if the service valve is closed, E-504: Error due to self diagnosis of compressor operation, E-505: Error due to self diagnosis of high pressure sensor, E-506: Error due to self diagnosis of low pressure sensor, E-560: Outdoor unit’s option switch setting error (when iinappropriate option switch is on), E-563: Error due to module installation of indoor unit with old version (Micom version needs to be checked), E-573: Error due to using single type outdoor unit in a module installation, E-601: Communication error between remote controller and the DVM Hydro unit / Hydro unit HT, E-602: Communication error between master and slave remote controller, E-604: Tracking error between remote controller and the DVM Hydro unit / Hydro unit HT, E-618: Error due to exceeding maximum numbers of Hydro unit installation (16 units), E-627: Error due to exceeding maximum numbers of wired remote controller installation (2 units), E-628: DMS↔Transmitter Communication Error, E-630: ERV wire remote controller normal ventilation option set error, E-631: ERVWire Remote controller auto ventilation option set error, E-632: Error when input the pulse except set the value of Pulse Width by PIM, E-633: Error caused by installing mixed models, E-652: Two wired remote controllers have been set to Master mode (COM1 wiring), E-653: Remote controller’s temperature sensor is disconnected or has problem, E-654: Data error on remote controller (Memory read/write error), E-701: Floating switch error on the indoor unit (1st detection), E-702: Error due to closed EEV of indoor unit (1st detection), E-703: Error due to opened EEV of indoor unit (1st detection), E-901: Error on the sensor of water inlet pipe (Short or Open), E-902: Error on the sensor of water outlet pipe (Short or Open), E-904: Error on water tank (Short or open), E-907: Error due to pipe rupture protection, E-908: Error due to freeze prevention (Re-operation is possible), E-909: Error due to freeze prevention (Re-operation is impossible), E-910: Water temperature sensor on water outlet pipe is detached, E-911: Flow switch off error, When the switch is turned off within 10 seconds after a pump starts its operation (Re-operation is possible), E-913: Six times detection for Flow Switch Error (Re-operation is not possible), E-914: Error due to incorrect thermostat connection, E-917: Water Tank Sensor Configutation Error, UP: Trial operation incompleted (UnPrepared) – It will be cleared when trial operation was executed for 1 hour or when automatic inspection is completed. If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB. Check if the outdoor unit service value is open. Check the compressor connection status Check the resistance between difference phases of the compressor. Check electrical connection and setting, Communication error between the outdoor and indoor unit. The table below list the self-diagnostic routines. Check the coolant charging status. SYSTEM AIR CONDITIONER. How do I fix an error E654 on my Samsung split AC? When an indoor unit indicator blinks, contact the nearest service center. [Inverter] IPM over current error. Wired remote controller COM2 option setting error. Samsung air conditioners can malfunction from time to time as conditioners of other brands do. Check if you have selected Fan/Turbo mode. najim July 19, 2020. one time my NIKAI split ac came E5, then I called technician. Note: dots … Check input power connection status. Check the compressor connection status. V 1.1.10. Reconfirm the opening of the service valve. Displayed in indoor unit. No error. Buonasera, mi sono appena iscritta sperando di poter trovare una soluzione al mio problema. These cookies do not store any personal information. Error due to operation failure of inverter compressor. OLP Overheat and Comp. Check the resistance between difference phases of the compressor. Check INVERTER MICOM. Cool/Warm air does not come out of the air conditioner. Protection of Outdoor Overload (when Comp. I have the same error code. Check the communication connection between indoor and outdoor units. Indoor unit Room Thermistor Open/Short. Pressthe Temp + or - button on the remote controller to change the set temperature. Thermal Fuse Open Check of indoor unit Terminal Block. If may not be a fire but it can be a steam generated by the defrost operation from outdoor heat exchanger during Heat mode in winter. how do I repair. Check sensor connection status. Check the power line and communication cable connection status. Check that the indoor/outdoor installation pipe/wiring are correct. L'assistenza clienti Samsung mi ha assegnato un centro assistenza di Milano. System stop due to discharge temperature. This website uses cookies to ensure you get the best experience Our, https://www.samsung.com/levant/air-conditioners, Hitachi AC Error Codes and Troubleshooting, Godrej AC Error Codes and Troubleshooting, Actron AC Error Codes and Troubleshooting, Fujitsu AC Error Codes and Troubleshooting, INDOOR MID, INDOOR IN PIPE-TH sensor error, DIS-TH(Discharge Temperature) Sensor Error, Prohibit Operation Condition Error (Heating), Prohibit Operation Condition Error (Cooling), Indoor unit room temperature sensor error (open / short), Indoor unit heat exchanger temperature sensor error (open / short), Lamp flickering-Lamp flickering-Lamp flickering, Lamp off -Lamp flickering-Lamp flickering, Abnormal communication error (Indoor - Outdoor unit), Lamp flickering-Lamp off -Lamp flickering, Outdoor unit temperature sensor error; Outdoor temp.-sensor, Deice temp.-sensor, OLP temp.-sensor, Discharge temp.-sensor, Heatsink temp.-sensor. Check if the appliance is running in a smoky area. Se hai modo di verificarlo, possiamo capire da cos'è dipeso il problema, altrimenti puoi contattare il supporto via chat per richiedere assistenza Check if the air conditioner is operating in De-ice mode.When the ice formed in winter or the outdoor temperature is too low, the air conditioner operates in De-ice mode automatically. Duplicated addresssetting error. Error on input current sensor of inverter 1 (Short or Open). If you want to operate the air conditioner in the sunlight, cover the outdoor unit using curtains or etc. We also use third-party cookies that help us analyze and understand how you use this website. The error indicated on the LED display of Indoor unit; Outdoor Unit Error mode and check method; Explanation: Communication error (indoor unable to receive data), Main checking Point: Communication cable connection, Explanation: Communication error (outdoor unable to communicate), Explanation: Indoor unit heat exchanger in temperature sensor error (Open/Short), Explanation: Indoor unit heat exchanger out temperature sensor error (Open/Short), Explanation: Indoor unit sensor error – Evaporator pipe in sensor detached, Explanation: Indoor unit sensor error – Evaporator pipe out sensor detached, Explanation: Indoor unit heat exchanger in & out temperature sensor detached, Main checking Point: Indoor unit operation mode, Explanation: The number of indoor unit mismatched, Main checking Point: Communication wiring, Explanation: Communication error (outdoor unable to receive data), Explanation: Communication error between 2 microcontroller on the outdoor PCB, Explanation: Condenser temperature sensor error (Short/Open), Explanation: Condenser temperature sensor detached, Explanation: Compressor discharge sensor error (Short/Open), Explanation: Compressor discharge sensor detached, Explanation: Compressor OLP sensor error (Short/Open), Explanation: Indoor unit heat exchanger freezing and compressor stop (cooling mode), Main checking Point: Check pipe matching also (indoor-outdoor), Explanation: Outdoor unit overload and compressor stop (protection control in heating mode), Explanation: Outdoor unit high discharge temperature and compressor stop, Main checking Point: Check pipe matching (indoor-outdoor), Explanation: Outdoor unit EEV open error (self diagnosis), Explanation: Outdoor unit EEV close error (self diagnosis), Explanation: High temperature (over 30˚C) of outdoor as heating mode, Explanation: Low temperature (under -5˚C) of indoor as cooling mode, Explanation: Wrong connection between communication and power cable, Main checking Point: Wiring indoor and outdoor, Explanation: Inverter Compressor starting failure (5 times), Main checking Point: Service valve, EEV, Compressor terminal, Compressor wire, Outdoor controller, Explanation: Compressor trip by input current limit control, Main checking Point: EEV, Gas over charge, Outdoor controller, Explanation: Compressor trip by OLP temperature limit control, Main checking Point: Outdoor fan, Compressor,  Outdoor controller, Explanation:  Compressor peak current protection, Main checking Point:  Outdoor fan, Compressor, Compressor wire, Outdoor controller, Explanation: Compressor overload protection by current, Main checking Point: Outdoor fan, EEV, Service valve, Outdoor controller, Explanation: DC-link voltage error (under 150V or over 410V), Main checking Point: Power voltage, Outdoor controller, Main checking Point: Compressor terminal, Compressor wire, Outdoor controller, Explanation:  DC-link voltage sensor error, Explanation: Compressor overload protection, Main checking Point: Outdoor fan, EEV, Service valve, Outdoor controller, Explanation: AC line zero-crossing detection circuit error, Main checking Point: Outdoor controller, Terminal Block, Explanation: NO GAS error (self diagnosis), Samsung VRF (DVM S) System AC Error Codes.